Condensate in Boilers: Formation, Properties, and Treatment

Formation of Condensate

In steam boiler systems, condensate is formed when steam, produced in the boiler, is transferred through piping to heat exchangers or steam jackets. As the steam releases heat, it cools and condenses, resulting in the formation of condensate water.

Key Facts

  1. Formation of Condensate: When steam is produced in a boiler, it is transferred through piping to heat exchangers or steam jackets. As the steam transfers heat, it cools down and condenses, forming condensate water.
  2. Impurities in Condensate: Condensate water typically has very few impurities. It is relatively pure compared to other water sources, as the impurities are left behind during the steam generation process.
  3. Corrosive Nature: Condensate from condensing boilers is acidic and corrosive due to the presence of acidic byproducts of fuel combustion. It can cause damage to piping systems, sewer lines, and other materials it comes in contact with.
  4. pH Level: The pH level of condensate can vary, but most condensate from natural gas appliances has a pH between 2.0 and 4.0. It is important to treat condensate to raise its pH to acceptable levels (close to 7) to prevent damage to drainage systems and the environment.
  5. Condensate Treatment: To neutralize the acidic condensate, a condensate neutralizer should be installed. These neutralizers typically contain alkaline limestone aggregate or chips that convert the acid into water, carbon dioxide, and mineral salts. Regular maintenance and replacement of the neutralizer media are recommended.
  6. Amount of Condensate: The amount of condensate produced depends on the boiler’s input and operating conditions. As a general rule of thumb, 3.5 liters of condensate are produced for every 30 kW of input when the boiler is operating in full condensing mode.

Impurities in Condensate

Condensate water generally contains minimal impurities compared to other water sources. The impurities present in the original water are left behind during the steam generation process, leaving the condensate relatively pure.

Corrosive Nature of Condensate

Condensate from condensing boilers is inherently acidic and corrosive due to the presence of acidic byproducts generated during fuel combustion. This acidic nature can cause damage to piping systems, sewer lines, and other materials that come into contact with the condensate.

pH Level of Condensate

The pH level of condensate can vary, but typically, condensate from natural gas appliances falls within a range of 2.0 to 4.0. It is crucial to treat condensate to raise its pH to acceptable levels (ideally close to 7) to prevent damage to drainage systems and the environment.

Condensate Treatment

To neutralize the acidic condensate, a condensate neutralizer should be installed. These neutralizers typically contain alkaline limestone aggregate or chips that react with the acid, converting it into water, carbon dioxide, and mineral salts. Regular maintenance and replacement of the neutralizer media are essential to ensure effective treatment.

Amount of Condensate Produced

The quantity of condensate produced is influenced by the boiler’s input and operating conditions. As a general rule, for every 30 kW of input, approximately 3.5 liters of condensate are generated when the boiler operates in full condensing mode.

Sources

  1. Bartingale Mechanical: Why is Condensate Water Treatment so important for Steam Boilers?
  2. Automatic Heating: Managing Condensate for Condensing Boilers
  3. Viessmann: What is a condensing boiler?

FAQs

What is condensate in a boiler?

Condensate in a boiler is the water formed when steam, produced by the boiler, cools and condenses. It is typically collected and returned to the boiler to save water and energy.

Why is condensate acidic and corrosive?

Condensate from condensing boilers is acidic and corrosive due to the presence of acidic byproducts generated during fuel combustion. This acidic nature can cause damage to piping systems, sewer lines, and other materials that come into contact with the condensate.

What is the pH level of condensate?

The pH level of condensate can vary, but typically, condensate from natural gas appliances falls within a range of 2.0 to 4.0. It is important to treat condensate to raise its pH to acceptable levels (ideally close to 7) to prevent damage to drainage systems and the environment.

How is condensate treated?

Condensate is treated using condensate neutralizers. These neutralizers contain alkaline limestone aggregate or chips that react with the acid in the condensate, converting it into water, carbon dioxide, and mineral salts. Regular maintenance and replacement of the neutralizer media are essential to ensure effective treatment.

How much condensate is produced in a boiler?

The amount of condensate produced depends on the boiler’s input and operating conditions. As a general rule, for every 30 kW of input, approximately 3.5 liters of condensate are generated when the boiler operates in full condensing mode.

Why is it important to treat condensate in a boiler system?

Treating condensate in a boiler system is important to neutralize its acidity and prevent damage to piping systems, sewer lines, and other materials that come into contact with the condensate. Additionally, proper treatment helps maintain the efficiency and longevity of the boiler system.

What are the consequences of not treating condensate in a boiler system?

Not treating condensate in a boiler system can lead to corrosion and damage to piping systems, sewer lines, and other components. It can also reduce the efficiency of the boiler and shorten its lifespan.

What are some common methods for treating condensate in a boiler system?

Common methods for treating condensate in a boiler system include using condensate neutralizers, pH adjustment, and chemical treatment. Condensate neutralizers are devices that contain alkaline materials to neutralize the acidity of the condensate. pH adjustment involves adding chemicals to raise the pH of the condensate to an acceptable level. Chemical treatment involves adding specific chemicals to the condensate to inhibit corrosion and protect the boiler system components.