What does 4 RMC weigh?



How much does a 4 in RMC weigh?

Galvanized Rigid Conduit (GRC)

Trade Size Metric Designator Approx Weight per 100 Ft (30.5M)
3 78 329.8
3 1/2 91 399.2
4 103 467.2
5 129 689.5

How much does a 4 rigid 90 weigh?

Galvanized Rigid Conduit (GRC) 90° Elbows

Trade Size Metric Approx Weight per 100 Pcs
2 1/2 63 623.2
3 78 927.6
3 1/2 91 1297.3
4 103 1596.2

What does a 4 EMT weigh?





Specification Data

Trade Size Approx Weight Per Ft. (.305M)
3″ 78 2.63
3-1/2″ 91 3.49
4″ 103 3.93
1 +/- 0.005″ (.13 mm) for trade sizes 1/2″ to 2″

How many feet are in a master bundle of 4 PVC?

Utility Duct – Type DB-120 for Direct Burial Rated for use with 90° C Wire

Trade Size Average O.D. (in) Crate Quantity (ft)
2 2.375 2800
3 3.500 1760
4 4.500 1140
5 5.563 760

What is RMC conduit?

Galvanized Rigid Steel Conduit (GRC, RMC) is the heaviest weight and thickest wall of electrical conduits. Allied Tube & Conduit®‘s Galvanized Rigid Steel Conduit is hot-dip galvanized for corrosion resistance and is considered non-combustible.

How long is a 4 inch rigid coupling?

1.66″ long





A: These couplings are 1.66″ long (about 1-5/8 “).

Can you use galvanized pipe for conduit?

o 344.14 Dissimilar Metals.



To make this transition a stainless-steel coupling or fitting can be used in between the stainless conduit/tubing and the galvanized conduit/tubing. However, a galvanized couplings and fittings should not be used to connect galvanized conduit/tubing to stainless steel conduit/tubing.

How much does a 10 foot rigid conduit weight?

33.2 Lb.

33.2 Lb. RMC (rigid metallic conduit) designed for the protection and routing of wire conductors.

What is the difference between EMT and RMC?

The biggest different between RMC and EMT is that EMT is a lot lighter. It has thinner walls and is also unthreaded. As a result, it’s a very popular option for use in commercial buildings. Connecting sections of EMT is easier.



What is the standard rigid conduit size?

RMC is available in trade sizes 1/2 through 6, and 10′ and 20′ lengths. RMC is threaded on both ends, with a coupling applied to one and a color-coded thread protector on the other.

What is the standard size of rigid steel conduit?

Electroline® Rigid Conduit (RSC) is produced in normal trade sizes from 1/2″ to 6″ in standard lengths of 10 feet (3.05 m). The rigid conduit is threaded on both ends, with a coupling applied to one end and a color coded by size thread protector to the other end.

How much does 4 PVC pipe weigh?

PVC and CPVC Pipe – Schedule 80

Nominal Pipe Size Outside Diameter Weight(lb/100 ft)
4 4.5 275
5 5.563 387
6 6.625 542
8 8.625 805

How much does PVC pipe weight per foot?

Schedule 80 PVC and CPVC Pipe Specifications

Size (in.) Wall Thickness (in.) Weight / Foot (lbs/ft.)
3/4 0.154 0.30
1 0.179 0.44
1 1/4 0.191 0.61
1 1/2 0.200 0.74

Where is PVC conduit not allowed?

Ambient temperature — PVC conduit isn’t permitted to be installed if the ambient temperature exceeds 50°C (122°F) [Sec. 352.12(D)].



How tall is a 4 PVC 90?

Dimension(s): 4.5″ L x 5.63″ W x 6.25″ H.

What is the deduction factor on a 3/4 inch 90?

The most common deducts are 5″ for ½” conduit, 6″ for ¾” conduit and 8″ for a 1″ bender. It is a function of the curvature radius of the bender and cannot be changed. The deduct for your bender should be stamped on the bender.

How do you bend a 4 point saddle on a Chicago bender?


Quote from video: Again like I said always keep the bend in front of you when you're bending saddles. Slide it forward flip it around 180 degrees line it up again another thing we don't want is what a dogleg.

How long is a 3 inch EMT 90?

EMT Large Radius 90° Elbows

Trade Size Metric Designator Straight (D)*
3 78 270
3 78 279
3 78 273
3 78

What’s the deduction for 3/4 rigid conduit?

3. On the conduit, measure from the free end to be bent up the calculated number and mark the conduit. As an example, to bend 3/4” EMT conduit have a free end height of 8.5”, the table indicates to subtract 6” from the 8.5” which leave 2.5” from the end to bend up to make the mark.



What is the deduction for a 2 inch EMT 90?

For a 90 stub up for a 2″ EMT the chart says Minimum stub length = 18-3/8″ and deduction (take up) for the mark #1 is 16-3/8″. The route that the conduits will take is; 50″ straight up to the top of first 90 (out of cabinet) changing from vertical to horizontal plane.